Ekoenergetyka error codes
This page covers Ekoenergetyka DC fast chargers (EKO90 and Axon range models, referenced 3-21-xx.xxxx). Ekoenergetyka publishes no code list: every code below was observed on charging stations supervised by Chargekeeper, with the label sent by the charger.
Where to read the code: in Chargekeeper, charging station list, connector details, Information
column (or the in-progress sessions list, Information column). It shows
"OCPP code - manufacturer code - information". See Manufacturer error codes.
How Ekoenergetyka reports its errors
The charger sends a dotted numeric code of 3 to 6 segments in the manufacturer code field (vendorErrorCode) (for example 4.50.2, 100.30.23, 2.41.0.0). The information field carries an English label, cut at 50 characters (OCPP 1.6 limit); some labels are technical tokens rather than sentences (rcd-dc, button:emergency-shutdown, batlow_sat). The OCPP code is almost always OtherError, sometimes EVCommunicationError.
-
A code ending in
.0may signal a return to normal: for example4.50.0"Power is no longer limited by module failure" after4.50.1or4.50.2(power reduced because of a power module). -
Codes ending in a large number (for example
51.1.4.5.131072) look like bit fields; their label is onlywarning. -
The same code can arrive with different labels (for example
1.1.7withrcd-dcorerror:power-loss).
The meaning of each segment of the code is not known. Ekoenergetyka's technical documentation (manuals, error list) is reserved to the EkoDocs partner portal, available after creating an account. The charger's local web console (CMC, Charger Management Console) shows the error history and error analysis. For a diagnosis, ask Ekoenergetyka or your maintenance partner for the error list.
Codes observed on our stations, not documented by Ekoenergetyka
These codes were received from charging stations supervised by Chargekeeper but are not in the
manufacturer's public documentation. The label is the one sent by the charging station itself.
| Code | Label sent by the charging station | OCPP code |
|---|---|---|
1.1.3 |
— | OtherError |
1.1.4 |
powsup_sat |
OtherError |
1.1.5 |
batlow_sat |
OtherError |
1.1.7 |
rcd-dc |
OtherError |
1.1.8 |
error:power-loss |
OtherError |
1.1.9 |
button:emergency-shutdown |
OtherError |
1.1.16 |
door-opened |
OtherError |
1.2.3 |
rcd-ac |
OtherError |
1.8.31 |
dlbs:error |
OtherError |
2.1.1 |
No communication with I/O device number '1'. |
OtherError |
2.1.2 |
No communication with I/O device number '2'. |
OtherError |
2.40.0.0 |
No communication with the CSS module. |
OtherError |
2.41.0.0 |
No communication with the control pilot controller |
OtherError |
3.4.0.4 |
The DC contactor is open but should be closed. |
OtherError |
3.9.0.5 |
Overvoltage |
OtherError |
3.10.0.5 |
Insulation fault. |
OtherError |
4.10.0.5 |
Insulation warning. |
OtherError |
4.50.0 |
Power is no longer limited by module failure. |
OtherError |
4.50.1 |
Reduced power due to power module malfunction. |
OtherError |
4.50.2 |
Reduced power due to power module malfunction. |
OtherError |
4.50.3 |
Reduced power due to power module failure. |
OtherError |
4.50.4 |
Reduced power due to power module failure. |
— |
4.50.5 |
Reduced power due to power module malfunction. |
OtherError |
10.8.30 |
dlbs:warning |
— |
50.1.1 |
No communication with the power module (package No |
— |
50.1.5 |
No communication with the power module (package No |
OtherError |
50.2.7 |
No communication with the power module (package No |
— |
50.5.4 |
No communication with the power module (package No |
— |
51.1.1.5.16908288 |
warning |
OtherError |
51.1.1.5.67108864 |
warning |
OtherError |
51.1.1.81.36175872 |
warning |
— |
51.1.2.5.16908288 |
warning |
OtherError |
51.1.2.81.36175872 |
warning |
— |
51.1.3.5.16908288 |
warning |
OtherError |
51.1.4.5.131072 |
warning |
OtherError |
51.1.4.5.16908288 |
warning |
OtherError |
51.1.4.5.33685504 |
warning |
OtherError |
51.1.5.5.16908288 |
warning |
OtherError |
51.2.3.81.36175872 |
warning |
— |
51.2.4.81.2621440 |
warning |
— |
51.2.4.81.36175872 |
warning |
— |
51.3.5.81.36175872 |
warning |
— |
51.3.6.81.36175872 |
warning |
— |
51.4.1.81.36175872 |
warning |
— |
51.4.2.81.36175872 |
warning |
— |
51.5.3.81.36175872 |
warning |
— |
51.5.4.81.36175872 |
warning |
— |
60.0.1 |
Overtemperature warning: reading 80.1, limit 80. |
OtherError |
61.0.1.3 |
Temperature reading timeout from sensor number 0 w |
OtherError |
61.1.2.3 |
Temperature reading timeout from sensor number 1 w |
OtherError |
61.2.3.3 |
Temperature reading timeout from sensor number 2 w |
OtherError |
61.3.4.3 |
Temperature reading timeout from sensor number 3 w |
OtherError |
61.4.1.3 |
Timeout reading temperature sensor 4.1. |
OtherError |
61.5.2.3 |
Timeout reading temperature sensor 5.2. |
OtherError |
61.6.1.3 |
Timeout reading temperature sensor 6.1. |
OtherError |
61.7.2.3 |
Timeout reading temperature sensor 7.2. |
OtherError |
62.0.2 |
Timeout to receive data from the fast measurement |
OtherError |
62.1.34 |
Timeout to receive data from the fast measurement |
OtherError |
62.1.35 |
Timeout to receive data from the fast measurement |
OtherError |
90.4.1.0 |
DLBS: master contactors malfunction |
— |
100.1.1 |
Could not find the PLC device. |
OtherError |
100.10.1 |
Interruption of the CP line. |
OtherError |
100.15.1 |
Timeout_TT_EVSE_SLAC_init |
OtherError |
100.15.2 |
Timeout_TT_EVSE_match_MNBC |
OtherError |
100.15.3 |
Timeout_TT_EVSE_match_session |
EVCommunicationError |
100.15.4 |
Timeout_TT_match_join |
OtherError |
100.15.20 |
CP Fallback - BEB. |
EVCommunicationError |
100.15.21 |
CP Fallback - BFB. |
EVCommunicationError |
100.30.2 |
Could not start TLS server (-1): setNonBlocking: f |
OtherError |
100.30.21 |
Timeout (20 [s], max: 20 [s]) for establishing TCP |
OtherError |
100.30.23 |
TCP/TLS connection closed by the EV. |
EVCommunicationError |
100.40.2 |
V2G sequence error. |
EVCommunicationError |
150.0.0 |
Vehicle error (CCS). |
EVCommunicationError |
150.1.0 |
warning |
OtherError |
240.0.0 |
— | OtherError |
240.1.101.17 |
— | PowerMeterFailure |
Sources
- EkoDocs, Ekoenergetyka technical documentation portal (access after registration) — https://ekoenergetyka.com/ekodocs-technical-documentation-portal/
- Ekoenergetyka, charging station embedded software (LEko firmware, CMC console) — https://ekoenergetyka.com/software-solutions/charging-station-embedded-software/
- E-Flux, Ekoenergetyka charger onboarding guide (unofficial source) — https://help.e-flux.io/en/articles/8459333-manual-ekoenergetyka