Ekoenergetyka error codes

Actualizado el 28 de octubre de 2026
Este artículo aún no está disponible en Español. Se muestra la versión en English.

This page covers Ekoenergetyka DC fast chargers (EKO90 and Axon range models, referenced 3-21-xx.xxxx). Ekoenergetyka publishes no code list: every code below was observed on charging stations supervised by Chargekeeper, with the label sent by the charger.

Where to read the code: in Chargekeeper, charging station list, connector details, Information
column (or the in-progress sessions list, Information column). It shows
"OCPP code - manufacturer code - information". See Manufacturer error codes.

How Ekoenergetyka reports its errors

The charger sends a dotted numeric code of 3 to 6 segments in the manufacturer code field (vendorErrorCode) (for example 4.50.2, 100.30.23, 2.41.0.0). The information field carries an English label, cut at 50 characters (OCPP 1.6 limit); some labels are technical tokens rather than sentences (rcd-dc, button:emergency-shutdown, batlow_sat). The OCPP code is almost always OtherError, sometimes EVCommunicationError.

  • A code ending in .0 may signal a return to normal: for example 4.50.0 "Power is no longer limited by module failure" after 4.50.1 or 4.50.2 (power reduced because of a power module).

  • Codes ending in a large number (for example 51.1.4.5.131072) look like bit fields; their label is only warning.

  • The same code can arrive with different labels (for example 1.1.7 with rcd-dc or error:power-loss).

The meaning of each segment of the code is not known. Ekoenergetyka's technical documentation (manuals, error list) is reserved to the EkoDocs partner portal, available after creating an account. The charger's local web console (CMC, Charger Management Console) shows the error history and error analysis. For a diagnosis, ask Ekoenergetyka or your maintenance partner for the error list.

Codes observed on our stations, not documented by Ekoenergetyka

These codes were received from charging stations supervised by Chargekeeper but are not in the
manufacturer's public documentation. The label is the one sent by the charging station itself.

Code Label sent by the charging station OCPP code
1.1.3 — OtherError
1.1.4 powsup_sat OtherError
1.1.5 batlow_sat OtherError
1.1.7 rcd-dc OtherError
1.1.8 error:power-loss OtherError
1.1.9 button:emergency-shutdown OtherError
1.1.16 door-opened OtherError
1.2.3 rcd-ac OtherError
1.8.31 dlbs:error OtherError
2.1.1 No communication with I/O device number '1'. OtherError
2.1.2 No communication with I/O device number '2'. OtherError
2.40.0.0 No communication with the CSS module. OtherError
2.41.0.0 No communication with the control pilot controller OtherError
3.4.0.4 The DC contactor is open but should be closed. OtherError
3.9.0.5 Overvoltage OtherError
3.10.0.5 Insulation fault. OtherError
4.10.0.5 Insulation warning. OtherError
4.50.0 Power is no longer limited by module failure. OtherError
4.50.1 Reduced power due to power module malfunction. OtherError
4.50.2 Reduced power due to power module malfunction. OtherError
4.50.3 Reduced power due to power module failure. OtherError
4.50.4 Reduced power due to power module failure. —
4.50.5 Reduced power due to power module malfunction. OtherError
10.8.30 dlbs:warning —
50.1.1 No communication with the power module (package No —
50.1.5 No communication with the power module (package No OtherError
50.2.7 No communication with the power module (package No —
50.5.4 No communication with the power module (package No —
51.1.1.5.16908288 warning OtherError
51.1.1.5.67108864 warning OtherError
51.1.1.81.36175872 warning —
51.1.2.5.16908288 warning OtherError
51.1.2.81.36175872 warning —
51.1.3.5.16908288 warning OtherError
51.1.4.5.131072 warning OtherError
51.1.4.5.16908288 warning OtherError
51.1.4.5.33685504 warning OtherError
51.1.5.5.16908288 warning OtherError
51.2.3.81.36175872 warning —
51.2.4.81.2621440 warning —
51.2.4.81.36175872 warning —
51.3.5.81.36175872 warning —
51.3.6.81.36175872 warning —
51.4.1.81.36175872 warning —
51.4.2.81.36175872 warning —
51.5.3.81.36175872 warning —
51.5.4.81.36175872 warning —
60.0.1 Overtemperature warning: reading 80.1, limit 80. OtherError
61.0.1.3 Temperature reading timeout from sensor number 0 w OtherError
61.1.2.3 Temperature reading timeout from sensor number 1 w OtherError
61.2.3.3 Temperature reading timeout from sensor number 2 w OtherError
61.3.4.3 Temperature reading timeout from sensor number 3 w OtherError
61.4.1.3 Timeout reading temperature sensor 4.1. OtherError
61.5.2.3 Timeout reading temperature sensor 5.2. OtherError
61.6.1.3 Timeout reading temperature sensor 6.1. OtherError
61.7.2.3 Timeout reading temperature sensor 7.2. OtherError
62.0.2 Timeout to receive data from the fast measurement OtherError
62.1.34 Timeout to receive data from the fast measurement OtherError
62.1.35 Timeout to receive data from the fast measurement OtherError
90.4.1.0 DLBS: master contactors malfunction —
100.1.1 Could not find the PLC device. OtherError
100.10.1 Interruption of the CP line. OtherError
100.15.1 Timeout_TT_EVSE_SLAC_init OtherError
100.15.2 Timeout_TT_EVSE_match_MNBC OtherError
100.15.3 Timeout_TT_EVSE_match_session EVCommunicationError
100.15.4 Timeout_TT_match_join OtherError
100.15.20 CP Fallback - BEB. EVCommunicationError
100.15.21 CP Fallback - BFB. EVCommunicationError
100.30.2 Could not start TLS server (-1): setNonBlocking: f OtherError
100.30.21 Timeout (20 [s], max: 20 [s]) for establishing TCP OtherError
100.30.23 TCP/TLS connection closed by the EV. EVCommunicationError
100.40.2 V2G sequence error. EVCommunicationError
150.0.0 Vehicle error (CCS). EVCommunicationError
150.1.0 warning OtherError
240.0.0 — OtherError
240.1.101.17 — PowerMeterFailure